Antibody Protein ELISA Kit from MyBioSource header Telephone 1.858.633.0165          
1.855.MyBioSource
Fax 1.858.633.0166    Email sales@mybiosource.com 
tel/fax
menu1 Home Products Ordering Company Help menu7
bottom
   MyBioSource  rightarrow Assay Kit Blog  rightarrow hsa-mir-421 Real-Time RT-PCR Detection and cel-mir-39-3p pcr kit  rightarrow LOG IN  rightarrow MY ACCOUNT  rightarrow CART CONTENTS  rightarrow CHECKOUT 
horiz bar
MyBioSource Blogs moreseparator
separator
 • EAF2 elisa kit blog
 • MIGF elisa kit blog
 • CTBP2 elisa kit blog
 • Nr4a2 elisa kit blog
 • RNLS elisa kit blog
 • TrxR2 elisa kit blog
 • DNMT1 elisa kit blog
 • MIF elisa kit blog
 • DS clia kit blog
 • GRP elisa kit blog
 • RNF166 elisa kit blog
 • MYH11 elisa kit blog
 • CHRNa1 elisa kit blog
 • ANKRD20A4 elisa kit blog
 • SCARB1 elisa kit blog
 • TMPRSS6 elisa kit blog
 • MIP1A elisa kit blog
 • OR8H2 elisa kit blog
 • CytoSelect Proliferating Cell Nuclear Antigen (PCNA) elisa kit blog
 • GUF1 elisa kit blog
separator
Blog Categories separator
separator
 • Assay Kit Blogs
 • Biochemical Blogs
 • cDNA Clone Blogs
 • Monoclonal Antibody Blogs
 • Polyclonal Antibody Blogs
 • Rec/Purified Protein Blogs
 • Popular Product Blogs
separator
Our Best Sellers moreseparator
separator
 • Hepatitis C Virus (HCV) NS-5 (a.a. 2212-2313) genotype 1, Re... Recombinant Protein
 • Goat Anti-Canine IgG (H+L) Secondary Antibody
 • Secreted Frizzled Related Protein (SFRP) ELISA Kit
 • solute carrier family 16, member 3 (monocarboxylic acid tran... ELISA Kit
 • SB 742457 Inhibitor
 • RNF4 ELISA Kit
 • Serum albumin, HSA ELISA Kit
 • Human Chorionic Gonadotropin (hCG) beta Antibody
 • unc-13 homolog A (C. elegans) (UNC13A) ELISA Kit
 • LSM8 Antibody
 • Integrin beta-1 (ITGB1) ELISA Kit
 • TLR6 Antibody
 • Apelin-12 (AP-12) ELISA Kit
 • Cellular tumor antigen p53 (tp53) Recombinant Protein
 downarrow more ...
separator

hsa-mir-421 Real-Time RT-PCR Detection and cel-mir-39-3p pcr kit product blog

separator
Posted on 2017-03-04 02:17:50 by mybiosource_staff
Share it on ...     
separator
separator
Tags: PCR Kit; Human PCR Kit; hsa-mir-421 Real-Time RT-PCR Detection and cel-mir-39-3p; hsa-mir-421 Real-Time RT-PCR Detection and cel-mir-39-3p pcr kit;
separator
The Human hsa-mir-421 Real-Time RT-PCR Detection and cel-mir-39-3p n/a (Catalog #MBS8244790) is a PCR Kit and is intended for research purposes only. The product is available for immediate purchase. The MBS8244790 PCR Kit recognizes Human (General) hsa-mir-421 Real-Time RT-PCR Detection and cel-mir-39-3p. MyBioSource\'s hsa-mir-421 Real-Time RT-PCR Detection and cel-mir-39-3p can be used in a range of immunoassay formats including, but not limited to, Real-time RT-PCR.
The Real-Time RT-PCR detection and cel-mir-39-3p calibration Kit contains the whole reagent including the stem-loop RT primer & specific PCR primer set for microRNA quantificaion and cel-mir-39-3p primer set for calibration. It provides a sensitive and specific method of real-time PCR for relative quantificating of miRNAs from total RNA samples. It is Ideal for validating microRNA expression profiling data and high-throughput applications. Trait lies in even highly homogized miRNAs can be accurately dicriminated ensurenced by stemloop RT primer and high specific miRNAs primer set. Researchers should empirically determine the suitability of the hsa-mir-421 Real-Time RT-PCR Detection and cel-mir-39-3p n/a for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process.

To buy or view more detailed product information and pricing, please click on the technical datasheet page below:


(Or you can also download the PDF Manual for complete product instructions).

Principle of the Assay||MiRNAs real-time Quantitation assay of miRNAs includes two steps, stem-loop RT and real-time PCR. Stem-loop RT primers bind to at the 3\' portion of miRNA molecules and are reverse transcribed with reverse transcriptase. Then, the RT product is quantified using real-time PCR that includes miRNA-specific forward primer, reverse primer and SYBR Green dye.

Background/Introduction: The miRNAs RT-PCR Quantitation Kit is a sensitive and specific method using real-time PCR for the detection and quantification of miRNAs (miRNA) from total RNA samples. miRNAs are small, single-stranded, ~19 - 23 nt RNA molecules encoded in the genomes of plants, animals, and viruses. Mature miRNAs enter the RNA-induced silencing complex (RISC) and guide the RISC to induce translational repression or endonucleolytic cleavage of specific target mRNAs. Unlike commonly used methods for detection of miRNAs, the miRNAs qPCR Quantitation Kit is more rapid and sensitive. This kit contains miRNA hsa-mir-421 and cel-mir-39-3p high specific RT and PCR primer set, with SYBR Green dye included. The stem-loop like miRNAs RT primer and the miRNAs high specific primer set ensure the RT and PCR reaction would not be interfered by the miRNAs precursors. The reaction template could be total RNA or cell lysates. The system enables highly sensitive detection from as few as 10 copies of a target miRNAs, with a broad dynamic range that supports accurate quantification of high-copy mRNA from up to 1 ug of total RNA. High specificity ensurenced by stemloop RT primer and high specific miRNAs primer set; even highly homogized miRNAs can be accurately dicriminated. Higher dynamic range and sensitivity of miRNAs quantification than conventional method (such as Northern blot & micro-array) with broad dynamic range of at least seven orders of magnitude, and in this ready to use formulation can quantify as few as 7 copies of a miRNA target in as little as 0.1 pg of total RNA. Less sample requirement Total RNA, cell lysate or purified samll RNA can work as the qPCR Quantitation Kit\'s template, even the genomic DNA contamination would not interfere in miRNAs quantification. miRNA synthetic standard can work as a standard curve when you need to know the absolute number of a miRNA in one cell or work as positive control when you need to know the relative expression ratio between miRNA and cel-mir-39-3p or 5S rRNA.

hsa-mir-421 Real-Time RT-PCR Detection and cel-mir-39-3p n/a

horiz bar
 SSL   Follow us on Facebook Follow us onTwitter Follow us on Google Plus Connect us on LinkedIn Subscribe to our RSS Feed for latest products and special promotions